{"id":3263,"date":"2024-06-27T10:19:05","date_gmt":"2024-06-27T15:19:05","guid":{"rendered":"https:\/\/chattmed.com\/shop\/?post_type=product&#038;p=3263"},"modified":"2026-03-02T10:41:59","modified_gmt":"2026-03-02T15:41:59","slug":"27812-9-diode-cluster","status":"publish","type":"product","link":"https:\/\/chattmed.com\/shop\/product\/27812-9-diode-cluster\/","title":{"rendered":"27812 &#8211; 9CLS 5x200mW 1040nM 9 Diode Cluster  LED 670NM"},"content":{"rendered":"<h5 data-start=\"0\" data-end=\"270\" data-rm-block-id=\"block-1\"><span style=\"color: #000000;\">27812 &#8211; 9CLS DIODE FOR LASER UNITS<\/span><\/h5>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: left;\" data-start=\"272\" data-end=\"285\" data-rm-block-id=\"block-3\"><span style=\"color: #000000;\">What it is<\/span><\/h2>\n<p style=\"text-align: left;\" data-start=\"409\" data-end=\"618\" data-rm-block-id=\"block-4\"><span style=\"color: #000000;\"><strong data-start=\"409\" data-end=\"421\">Purpose:<\/strong> Delivers photo biomodulation \/ low-level laser therapy over a <strong data-start=\"483\" data-end=\"504\">medium-sized area<\/strong>\u2014bigger than a single-diode probe, smaller than the 33-diode head (27808).<\/span><\/p>\n<p style=\"text-align: left;\" data-start=\"620\" data-end=\"640\" data-rm-block-id=\"block-5\"><span style=\"color: #000000;\">The 9CLS model features a unique design that allows for effective treatment using the diode cluster technology.<\/span><\/p>\n<h2 style=\"text-align: left;\" data-start=\"620\" data-end=\"656\" data-rm-block-id=\"block-6\"><span style=\"color: #000000;\">Diodes &amp; wavelengths (core specs)<\/span><\/h2>\n<p style=\"text-align: left;\" data-start=\"657\" data-end=\"756\" data-rm-block-id=\"block-7\"><span style=\"color: #000000;\">Total <strong data-start=\"663\" data-end=\"677\">9 emitters<\/strong> with <strong data-start=\"683\" data-end=\"717\">~1040 mW (1.04 W) total output<\/strong>:<\/span><\/p>\n<ul style=\"text-align: left;\">\n<li data-start=\"761\" data-end=\"781\" data-rm-block-id=\"block-8\"><span style=\"color: #000000;\"><strong data-start=\"761\" data-end=\"781\">5 \u00d7 Laser diodes<\/strong><\/span><\/li>\n<li data-start=\"787\" data-end=\"853\" data-rm-block-id=\"block-9\"><span style=\"color: #000000;\"><strong data-start=\"787\" data-end=\"797\">850 nm<\/strong>, <strong data-start=\"799\" data-end=\"814\">200 mW each<\/strong> (infrared, deeper tissue targeting).<\/span><\/li>\n<li data-start=\"857\" data-end=\"875\" data-rm-block-id=\"block-10\"><span style=\"color: #000000;\"><strong data-start=\"857\" data-end=\"875\">4 \u00d7 LED diodes<\/strong><\/span><\/li>\n<li data-start=\"881\" data-end=\"946\" data-rm-block-id=\"block-11\"><span style=\"color: #000000;\"><strong data-start=\"881\" data-end=\"891\">670 nm<\/strong>, <strong data-start=\"893\" data-end=\"907\">10 mW each<\/strong> (red light, more superficial targets).<\/span><\/li>\n<li data-start=\"948\" data-end=\"975\" data-rm-block-id=\"block-12\"><span style=\"color: #000000;\"><strong data-start=\"948\" data-end=\"973\">Why that mix matters:<\/strong><\/span><\/li>\n<li data-start=\"978\" data-end=\"1052\" data-rm-block-id=\"block-13\"><span style=\"color: #000000;\"><strong data-start=\"978\" data-end=\"998\">850 nm IR lasers<\/strong> \u2192 penetrate deeper (muscle, tendon, joint capsule).<\/span><\/li>\n<li data-start=\"1055\" data-end=\"1156\" data-rm-block-id=\"block-14\"><span style=\"color: #000000;\"><strong data-start=\"1055\" data-end=\"1074\">670 nm red LEDs<\/strong> \u2192 more surface\/near-surface tissues (skin, superficial tendon, trigger points).<\/span><\/li>\n<li data-start=\"1159\" data-end=\"1270\" data-rm-block-id=\"block-15\"><span style=\"color: #000000;\">Cluster layout gives <strong data-start=\"1180\" data-end=\"1205\">more uniform coverage<\/strong> than a single spot beam.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: left;\" data-start=\"1272\" data-end=\"1297\" data-rm-block-id=\"block-17\"><span style=\"color: #000000;\">Power &amp; treatment area<\/span><\/h2>\n<ul style=\"text-align: left;\">\n<li data-start=\"1300\" data-end=\"1369\" data-rm-block-id=\"block-18\"><span style=\"color: #000000;\"><strong data-start=\"1300\" data-end=\"1316\">Total power:<\/strong> <strong data-start=\"1317\" data-end=\"1328\">1040 mW<\/strong>. <span class=\"\" data-state=\"closed\"><span class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"><a class=\"flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]!\" style=\"color: #000000;\" href=\"https:\/\/www.chattanoogarehab.com\/us\/9-diode-cluster-1040-mw-27812?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\"><span class=\"relative start-0 bottom-0 flex h-full w-full items-center\"><span class=\"flex h-4 w-full items-center justify-between\"><span class=\"max-w-[15ch] grow truncate overflow-hidden text-center\">Chattanooga Rehab<\/span><span class=\"-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]\">+1<\/span><\/span><\/span><\/a><\/span><\/span><\/span><\/li>\n<li data-start=\"1372\" data-end=\"1485\" data-rm-block-id=\"block-19\"><span style=\"color: #000000;\"><strong data-start=\"1372\" data-end=\"1407\">Suggested area size by vendors:<\/strong> roughly <strong data-start=\"1416\" data-end=\"1428\">5\u201310 cm\u00b2<\/strong> treatment zones. <span class=\"\" data-state=\"closed\"><span class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"><a class=\"flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]!\" style=\"color: #000000;\" href=\"https:\/\/www.wsent.biz\/products\/chattanooga-27812-9-diode-cluster?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\"><span class=\"relative start-0 bottom-0 flex h-full w-full items-center\"><span class=\"flex h-4 w-full items-center justify-between overflow-hidden\"><span class=\"max-w-[15ch] grow truncate overflow-hidden text-center\">WS Enterprises and Associates, Inc.<\/span><\/span><\/span><\/a><\/span><\/span><\/span><\/li>\n<li data-start=\"1488\" data-end=\"1652\" data-rm-block-id=\"block-20\"><span style=\"color: #000000;\"><strong data-start=\"1488\" data-end=\"1513\">Clinical implication:<\/strong> faster than a single diode for mid-size regions (e.g., small muscle groups, localized joint pain).<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: left;\" data-start=\"1654\" data-end=\"1705\" data-rm-block-id=\"block-22\"><span style=\"color: #000000;\">Operating \/ software features (what you control)<\/span><\/h2>\n<p style=\"text-align: left;\" data-start=\"1706\" data-end=\"1823\" data-rm-block-id=\"block-23\"><span style=\"color: #000000;\">When plugged into a compatible Chattanooga base unit, the 27812 head enables: <span class=\"\" data-state=\"closed\"><span class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\" data-testid=\"webpage-citation-pill\"><a class=\"flex h-4.5 overflow-hidden rounded-xl px-2 text-[9px] font-medium transition-colors duration-150 ease-in-out text-token-text-secondary! bg-[#F4F4F4]! dark:bg-[#303030]!\" style=\"color: #000000;\" href=\"https:\/\/chattmed.com\/shop\/product\/27812-9-diode-cluster\/?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\"><span class=\"relative start-0 bottom-0 flex h-full w-full items-center\"><span class=\"flex h-4 w-full items-center justify-between\"><span class=\"max-w-[15ch] grow truncate overflow-hidden text-center\">Chattanooga Medical Supply<\/span><span class=\"-me-1 flex h-full items-center rounded-full px-1 text-[#8F8F8F]\">+1<\/span><\/span><\/span><\/a><\/span><\/span><\/span><\/p>\n<ul style=\"text-align: left;\">\n<li data-start=\"1826\" data-end=\"1894\" data-rm-block-id=\"block-24\"><span style=\"color: #000000;\"><strong data-start=\"1826\" data-end=\"1863\">Independent control of parameters<\/strong> (power, time, dosage, etc.).<\/span><\/li>\n<li data-start=\"1826\" data-end=\"1894\" data-rm-block-id=\"block-25\"><span style=\"color: #000000;\"><strong data-start=\"1897\" data-end=\"1932\">Dose display in Joules or J\/cm\u00b2<\/strong> (energy density).<\/span><\/li>\n<li data-start=\"1955\" data-end=\"2031\" data-rm-block-id=\"block-26\"><span style=\"color: #000000;\"><strong data-start=\"1955\" data-end=\"1986\">Continuous and pulsed modes<\/strong> with <strong data-start=\"1992\" data-end=\"2028\">fully variable pulse frequencies<\/strong>.<\/span><\/li>\n<li data-start=\"2034\" data-end=\"2097\" data-rm-block-id=\"block-27\"><span style=\"color: #000000;\"><strong data-start=\"2034\" data-end=\"2056\">Real-time feedback<\/strong> showing energy delivered as you treat.<\/span><\/li>\n<li data-start=\"2100\" data-end=\"2160\" data-rm-block-id=\"block-28\"><span style=\"color: #000000;\"><strong data-start=\"2100\" data-end=\"2131\">Preset clinical indications<\/strong> matched to the applicator.<\/span><\/li>\n<li data-start=\"2100\" data-end=\"2160\" data-rm-block-id=\"block-29\"><span style=\"color: #000000;\"><strong data-start=\"2163\" data-end=\"2194\">User-defined protocol slots<\/strong> for saving custom treatments.<\/span><\/li>\n<\/ul>\n<h2 style=\"text-align: left;\" data-start=\"2226\" data-end=\"2242\" data-rm-block-id=\"block-30\"><\/h2>\n<h2 style=\"text-align: left;\" data-start=\"2226\" data-end=\"2242\" data-rm-block-id=\"block-31\"><span style=\"color: #000000;\">Compatibility<\/span><\/h2>\n<ul style=\"text-align: left;\">\n<li data-start=\"2245\" data-end=\"2449\" data-rm-block-id=\"block-32\"><span style=\"color: #000000;\">Designed for Chattanooga <strong data-start=\"2270\" data-end=\"2330\">Vectra Genisys \/ Genisys TranSport laser therapy systems<\/strong> (also listed as working with some NEO combo units depending on configuration)<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: left;\" data-start=\"2451\" data-end=\"2473\" data-rm-block-id=\"block-34\"><span style=\"color: #000000;\">Safety \/ class note<\/span><\/h2>\n<ul>\n<li style=\"text-align: left;\" data-start=\"2474\" data-end=\"2694\" data-rm-block-id=\"block-35\"><span style=\"color: #000000;\">This applicator is part of a <strong data-start=\"2503\" data-end=\"2540\">Class 3B therapeutic laser system<\/strong> when used with its base. That means standard clinical laser precautions apply (eye protection, controlled use).<\/span><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Fully functional device with continuous and pulsed modes, offering real-time feedback and a wide variety of LED and laser options, including diode cluster.<br \/>\n\u2022 User-defined protocol slots on board<br \/>\n\u2022 Easy connection to existing Vectra Genisys Electrotherapy or Combination device.<\/p>\n","protected":false},"featured_media":1038,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[805],"product_cat":[169],"product_tag":[585,570,569,1126,443,1127,1125,187,444,912,568],"class_list":{"0":"post-3263","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-chattanooga","7":"product_cat-laser","8":"product_tag-585","9":"product_tag-9-diode-cluster","10":"product_tag-9cls","11":"product_tag-9cls-diode","12":"product_tag-diode","13":"product_tag-diode-9-cls","14":"product_tag-diodes","15":"product_tag-laser","16":"product_tag-laser-diode","17":"product_tag-laser-head","18":"product_tag-led-diode","21":"onbackorder","22":"sale","23":"taxable","24":"shipping-taxable","25":"purchasable","26":"product-type-simple","27":"product-grid-view"},"_links":{"self":[{"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/product\/3263","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/comments?post=3263"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/media\/1038"}],"wp:attachment":[{"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/media?parent=3263"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/product_brand?post=3263"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/product_cat?post=3263"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/product_tag?post=3263"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}