{"id":67,"date":"2017-09-16T22:16:35","date_gmt":"2017-09-17T03:16:35","guid":{"rendered":"https:\/\/chattmed.com\/shop\/product\/intelect-legend-xt-transport-2-cm-soundhead\/"},"modified":"2026-03-31T14:03:26","modified_gmt":"2026-03-31T19:03:26","slug":"27382-legend-xt-2-cm-sound-head","status":"publish","type":"product","link":"https:\/\/chattmed.com\/shop\/product\/27382-legend-xt-2-cm-sound-head\/","title":{"rendered":"2 CM2 Sound Head for Intelect Legend XT \/ Transport Units &#8211; 27382"},"content":{"rendered":"<h5 data-rm-block-id=\"block-1\"><strong># 27382 &#8211; INTELECT LEGEND XT \/ TRANSPORT SYSTEM 1 CM\u00b2 &#8211; SOUND HEAD APPLICATOR<\/strong><\/h5>\n<p data-rm-block-id=\"block-2\"><strong>\u00a0<\/strong><\/p>\n<p data-rm-block-id=\"block-3\">\n<ul>\n<li data-rm-block-id=\"block-4\"><span style=\"color: #000000;\">Waterproof and pre-calibrated applicators<\/span><\/li>\n<li data-rm-block-id=\"block-5\"><span style=\"color: #000000;\">Available in 1cm, 2cm, 5cm and 10 CM\u00b2 Sizes.<\/span><\/li>\n<li data-rm-block-id=\"block-6\"><span style=\"color: #000000;\">1 &amp; 3.3 Mhz Output<\/span><\/li>\n<li data-rm-block-id=\"block-7\"><span style=\"color: #000000;\">1 year manufacture warranty, against all defects (Except dropping or destroying the crystal by user error)<\/span><\/li>\n<\/ul>\n<p data-rm-block-id=\"block-8\">\n<p data-rm-block-id=\"block-9\">\n<p data-rm-block-id=\"block-10\"><span style=\"color: #000000;\"><strong>Made for the following machines:<\/strong><\/span><\/p>\n<p data-rm-block-id=\"block-11\">\n<p data-rm-block-id=\"block-12\"><span style=\"color: #000000;\"><u>Model Numbers:<\/u><\/span><\/p>\n<p data-rm-block-id=\"block-13\">\n<p data-rm-block-id=\"block-14\"><span style=\"color: #000000;\">2760 ( Intelect legend XT 2-Channel Combo)<\/span><br \/>\n<span style=\"color: #000000;\">2788 (Intelect legend XT 4-Channel Combo)<\/span><br \/>\n<span style=\"color: #000000;\">2782 (Intelect legend Transport U.S. ONLY)<\/span><br \/>\n<span style=\"color: #000000;\">2738 (Intelect legend Transport Combo)<\/span><\/p>\n<p data-rm-block-id=\"block-15\">\n<p data-rm-block-id=\"block-16\"><span style=\"color: #000000;\"><strong>THIS APPLICATOR ONLY FITS THE INTELECT LEGEND XT UNITS AND DOES NOT FIT THE OLDER BEIGE INTELECT LEGEND OR ANY VECTRA GENISYS UNIT \/ Intelect legend 2.<\/strong><\/span><\/p>\n<p data-rm-block-id=\"block-17\">\n<p data-rm-block-id=\"block-18\"><span style=\"color: #000000;\">IF YOU ARE UNSURE OF WHICH UNIT YOU HAVE, PLEASE DO NOT HESITATE TO CALL US AT: 423-870-9030<\/span><\/p>\n<p data-rm-block-id=\"block-19\">\n<p data-rm-block-id=\"block-20\"><span style=\"color: #000000;\">It is important to note that these units must use Ultrasound Gel to be coupled properly, ensuring that U.S. waves are being transmitted properly.\u00a0 \u00a0(The new Intelect Legend 2 does not use U.S. Gel Directly on the head, must be dry when activated and the gel goes on the skin directly)<\/span><\/p>\n<p data-rm-block-id=\"block-21\">\n<ol>\n<li data-rm-block-id=\"block-22\"><span style=\"color: #000000;\">The item code 27382 refers to a replacement 2 cm2 applicator for a Chattanooga U.S.\/E-stim combo unit.<\/span><\/li>\n<\/ol>\n<p data-rm-block-id=\"block-23\">\n<ol start=\"2\">\n<li data-rm-block-id=\"block-24\"><span style=\"color: #000000;\">It is important to replace the applicator when it is no longer functioning properly and cannot be repaired or calibrated.<\/span><\/li>\n<\/ol>\n<p data-rm-block-id=\"block-25\">\n<ol start=\"3\">\n<li data-rm-block-id=\"block-26\"><span style=\"color: #000000;\">Regular maintenance and inspection can help determine when a replacement is necessary, e.g. Cord frayed, no output, error codes, no coupling, etc.<\/span><\/li>\n<\/ol>\n<p data-rm-block-id=\"block-27\">\n<ol start=\"4\">\n<li data-rm-block-id=\"block-28\"><span style=\"color: #000000;\">Signs that indicate the need for replacement include decreased effectiveness in ultrasound therapy and visible damage to the sound head as well as Output and Feedback from the patient.\u00a0 If the sound head does not heat correctly, that could also be a problem. (These sound heads do not heat up only slightly higher than the body temperature)<\/span><\/li>\n<\/ol>\n<p data-rm-block-id=\"block-29\">\n<ol start=\"5\">\n<li data-rm-block-id=\"block-30\"><span style=\"color: #000000;\">Replacing \/ recalibrating the applicator ensures optimal performance and accurate treatment delivery and better treatment outcomes.<\/span><\/li>\n<\/ol>\n<p data-rm-block-id=\"block-31\">\n<ol start=\"6\">\n<li data-rm-block-id=\"block-32\"><span style=\"color: #000000;\">Healthcare professionals should be aware of the specific item code when ordering a replacement sound head (There are more than 1 size of sound head) this page is for the 2 cm2.<\/span><\/li>\n<\/ol>\n<p data-rm-block-id=\"block-33\">\n<ol start=\"7\">\n<li data-rm-block-id=\"block-34\"><span style=\"color: #000000;\">It is recommended to consult the <a style=\"color: #000000;\" href=\"https:\/\/chattmed.com\/shop\/wp-content\/uploads\/2017\/09\/Genisys-XT-Service-Manual.pdf\">manufacturer&#8217;s guidelines<\/a> for Chattanooga U.S. \/ combo units regarding the maintenance schedule for the applicator. (Yearly calibration is needed to be in compliance with audits)<\/span><\/li>\n<\/ol>\n<p data-rm-block-id=\"block-35\">\n<ol start=\"8\">\n<li data-rm-block-id=\"block-36\"><span style=\"color: #000000;\">Regularly replacing\/calibrating the applicator helps maintain the quality and reliability of ultrasound therapy output and patient recovery time.<\/span><\/li>\n<\/ol>\n<p data-rm-block-id=\"block-37\">\n<ol start=\"9\">\n<li data-rm-block-id=\"block-38\"><span style=\"color: #000000;\">Healthcare professionals should educate patients (if applicable) on the importance of timely soundhead replacement \/ re-calibration for effective treatment outcomes and better patient recovery.<\/span><\/li>\n<\/ol>\n<p data-rm-block-id=\"block-39\">\n<ol start=\"10\">\n<li data-rm-block-id=\"block-40\"><span style=\"color: #000000;\">If you are unsure if your sound head or needs to be replaced or re-calibrated, please give us a call directly. 423-870-9030<\/span><\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #000000;\">Other information(manual) : <a style=\"color: #000000;\" href=\"https:\/\/www.manualslib.com\/products\/Chattanooga-Group-Intelect-Legend-Xt-9075548.html\" target=\"_blank\" rel=\"noopener\">Chattanooga group Intelect Legend XT Manuals | ManualsLib<\/a><\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>2 CM\u00b2 &#8211; SOUND HEAD APPLICATOR INTELECT LEGEND XT \/ TRANSPORT SYSTEM &#8211; Direct replacement, pre-calibrated, waterproof, 1-year warranty. -Chattanooga Medical Supply<\/p>\n","protected":false},"featured_media":6427,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[805],"product_cat":[24],"product_tag":[798,801,231,263,800,210,220,797,221,211,799,222,795],"class_list":{"0":"post-67","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_brand-chattanooga","7":"product_cat-replacement-soundheads-and-leadwires","8":"product_tag-2-cm","9":"product_tag-2-cm2","10":"product_tag-2-cm2-sound-head","11":"product_tag-263","12":"product_tag-2cm2","13":"product_tag-applicator","14":"product_tag-intelect-legend-xt-sound-head","15":"product_tag-intelect-xt-sound-head","16":"product_tag-legend-xt-transducer","17":"product_tag-sound-head","18":"product_tag-sound-head-2-cm","19":"product_tag-transducer","20":"product_tag-ultrasound-transducer","23":"onbackorder","24":"sale","25":"taxable","26":"shipping-taxable","27":"purchasable","28":"product-type-simple","29":"product-grid-view"},"_links":{"self":[{"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/product\/67","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/comments?post=67"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/media\/6427"}],"wp:attachment":[{"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/media?parent=67"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/product_brand?post=67"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/product_cat?post=67"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/chattmed.com\/shop\/wp-json\/wp\/v2\/product_tag?post=67"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}