Description
Intelect Legend XT Channel 3 Lead Wire – Chattanooga 27314
The Intelect Legend XT Channel 3 Lead Wire, Chattanooga Item Code 27314, is a replacement patient lead wire for the Channel 3 electrotherapy output on compatible Chattanooga therapy systems.
The lead wire provides the connection between the electrotherapy unit and the patient electrodes, allowing the selected electrical stimulation waveform to be delivered during treatment.
If the original Channel 3 lead wire has become damaged, intermittent, worn, or no longer maintains a dependable connection, Chattanooga 27314 is the correct replacement Channel 3 lead wire for compatible systems.
Chattanooga 27314 Compatibility
The 27314 Channel 3 Lead Wire is designed for use with compatible:
- Chattanooga Intelect Legend XT
- Chattanooga Vectra Genisys
- Chattanooga Intelect Transport
For Intelect Legend XT systems, Channels 3 and 4 are available on systems equipped with the 4-channel electrotherapy configuration or Channel 3/4 electrotherapy module.
Always verify the model and configuration of your therapy system before ordering.
What Does the Channel 3 Lead Wire Do?
The Intelect Legend XT Channel 3 Lead Wire connects the Channel 3 electrotherapy output to the electrodes placed on the patient.
During electrical stimulation treatment, the therapy unit generates the selected waveform and sends it through the patient lead wire to the electrodes.
Because lead wires are repeatedly connected, disconnected, bent, wrapped, and stored during normal clinical use, they can eventually develop internal or external damage.
A failing lead wire may result in:
- Intermittent stimulation
- Loss of Channel 3 output
- Treatment interruptions
- Electrode connection errors
- Output changing when the wire is moved
- Loose or damaged connectors
- Visible cuts or deterioration in the lead wire
Replacing a damaged lead wire can restore a reliable connection without replacing the entire electrotherapy system.
Channel 3 Specific Replacement
Chattanooga uses separate lead wires for each electrotherapy channel.
The corresponding Chattanooga lead-wire part numbers are:
- 27312 – Channel 1 Lead Wire
- 27313 – Channel 2 Lead Wire
- 27314 – Channel 3 Lead Wire
- 27315 – Channel 4 Lead Wire
P/N 27314 is specifically the Channel 3 lead wire.
Using the proper channel-specific lead wire also makes it easier for clinicians to identify and organize the connections during multi-channel electrotherapy treatments.
Rip-Stop Design
The Chattanooga 27314 patient lead wire incorporates a rip-stop design intended to improve durability during repeated clinical use.
The lead-wire series also uses color-coded connectors to help clinicians distinguish one treatment channel from another.
These features are especially useful in busy physical therapy, rehabilitation, chiropractic, and sports medicine facilities where electrotherapy equipment may be used throughout the day.
Intelect Legend XT 4-Channel Systems
The 27314 Channel 3 Lead Wire is particularly important for Intelect Legend XT systems equipped for four-channel electrotherapy.
Channels 3 and 4 allow compatible Legend XT systems to provide additional electrotherapy treatment channels beyond the standard Channels 1 and 2.
If Channel 3 is producing intermittent or inconsistent stimulation while the other channels function normally, the patient lead wire is one of the components that should be inspected during troubleshooting.
Testing with a known-good lead wire can help determine whether the problem originates from the lead wire, electrodes, or the electrotherapy unit itself.
Product Details
- Manufacturer: Chattanooga
- Item Code / Part Number: 27314
- Product: Electrotherapy Patient Lead Wire
- Channel: Channel 3
- Primary Compatibility: Intelect Legend XT
- Additional Compatibility: Vectra Genisys and Intelect Transport
- Design: Rip-stop patient lead wire
- Application: Electrotherapy / Electrical Stimulation
- Quantity: 1 Lead Wire
- Primary Keyword: Intelect Legend XT Channel 3 Lead Wire
Need Another Chattanooga Lead Wire?
Use the following part numbers when replacing lead wires on compatible Chattanooga electrotherapy systems:
27312 – Channel 1
27313 – Channel 2
27314 – Channel 3
27315 – Channel 4
Be sure to select the correct channel when ordering. (They are all interchangeable) (Channel 1 can fit into all channels, etc)
Need Help Finding the Correct Chattanooga Part?
If you are unsure whether Chattanooga 27314 is compatible with your therapy system, contact us with the model and serial number of your unit.
We can help identify the correct patient lead wire, accessory, or replacement part for your Intelect Legend XT, Vectra Genisys, or Intelect Transport syste
Made for the following machines:
Model numbers:
- 2760 (intelect legend XT 2-Channel Combo)
- 2763 (intelect legend XT 2-Channel Electrotherapy)
- 2786 (Intelect legend XT 4-Channel Electrotherapy)
- 2788 (Intelect legend XT 4-Channel Combo)
- 2782 (Intelect legend Transport Ultrasound)
- 2738 (Intelect legend Transport Combo)
- 2783 (Intelect legend Transport 2-Channel Electrotherapy)
- Vectra Genisys