Vectra Genisys Laser ONLY

$1,422.70 $2,678.40

Vectra Genisys – Laser Only – Fully functional device with independent control over all parameters
Display of dosage in choice of joules or joules/cm². Continuous and pulsed treatment modes Real time feedback of dosage delivered Useful selection of clinical indications & user defined protocols

 

 

Description

Vectra Genisys – Laser Only – MUST BUY LASER HEAD SEPARATELY –   Please take a look at our options for laser sound heads at: Laser Heads.

 

  • Fully functional device with independent control over all parameters
  • Display of dosage in choice of joules or joules/cm²
  • Continuous and pulsed treatment modes
  • Real time feedback of dosage delivered
  • Useful selection of clinical indications & user defined protocols
  • Choice of 8 interchangeable Laser Diode and Cluster Applicators with power ranging from 100mW-1440mW (purchased separately)
  • Electronic Signature Recognition allows allows each laser applicator to be used in a “plug-and-use” format
  • Laser Therapy can be controlled from the laser applicator
  • Lightweight design, along with battery-powered option and custom designed mobile carrying bag, make transport easy
  • Unit designed for table top, wall mount or mobile use
  • protective eye-wear included (2x)

 

Vectra Genisys Laser-only:

 

Continuous Mode – The output of the laser light is not interrupted during the treatment time.

Dosage – A measure of the intensity of the light energy over the treatment area. The unit of measure is Joules or Joules/cm2

.
Energy – Measured in Joules, energy equals the treatment time multiplied by the power. More importantly, Energy Density equals
the power output multiplied by the treatment time, and divided by the spot size (cm2 ). This gives a more specific measurement of
energy delivered.

Frequency – Pulsed frequencies are selectable from 8 to 10,000 Hz.

Heads – The clear lens face of the applicator that contacts the patient’s skin. It consists of laser diodes with or without LED’s or
SLD’s (depending on the applicator).

Power – Measured in Watts (W), power wattage is directly proportional to the treatment time and penetration of the laser light
energy. High-powered diodes will reduce patients’ treatment time and give a higher amount of energy at a deeper depth. Power
output can be either continuous or pulsed.

Power Density – Ratio of power divided by treatment time.

Pulsed Mode – This is the ratio of the “On” time to “Total” time of the cycle, expressed as a percentage. The lower the percentage, the
lower temporal average intensity. 100% is continuous laser light. Pulsed Mode is 90% on and 10% off.

NOTE: Pulsed Mode is also equivalent to Duty Cycle.

Spot Size – Area of the LED, SLD, or other beam when it leaves the face of the lens.

Treatment Area – Area of tissue affected by LED, SLD, or laser when wavelength, divergence angles, and depth of penetration are
factored. This is the area used to calculate dosage.

Treatment Time – Measured in seconds, it is the suggested time per point that therapy is given.

 

 

 

Your Shopping cart

Close